Siemens Sinumerik 810T User Manual page 139

Basic version 3, software version 3
Table of Contents

Advertisement

3 Operating Sequences
3.1.9 TRANSMIT coordinate transformation
State / event matrix for transformation selection and deselection:
State
Automatic
Ereignis
passive
Event
NC Start
Automatic
active
NC Stop
Change to
JOG
JOG
Change to
AUTOMATIC
RESET
Automatic
passive
1)
Deselec-
tion of
transform.
Change to
Deselection
REFPOINT
of transform.
1)
Note
Case 1:
Transformation deselection on RESET: RESET is caused by pressing the RESET key, part programm
(PP) end and mode change except REFPOINT.
Case 2:
No transformation deselection on RESET: generally transformation modal except for REFPOINT.
Explanations of the state/event matrix:
The fields within the matrix contain the state subsequent to the event and information on the
transformation state.
"AUTOMATIC passive" state:
No program is being executed (Reset).
"AUTOMATIC active" state:
The program is being executed (program running).
"JOG" state:
You can traverse manually in the mode "JOG", "INC" or "REPOS".
"JOG" (AUTOMATIC interrupted) state:
The program was interrupted and the "JOG" state selected.
"AUTOMATIC interrupted" state:
The programm was interrupted, without leaving the "AUTOMATIC" mode (NC Stop).
3-38
Automatic
JOG
active
Automatic
interrupted
JOG
(Automatic
interrupted)
Automatic
passive
Automatic
JOG
passive
1)
1)
Deselec-
Deselec-
tion of
tion of
transform.
transform.
Deselection
Deselection
of transform.
of transform.
© Siemens AG 1990 All Rights Reserved
JOG
Automatic
(Automatic
interrupted
interrupted)
Automatik
active
JOG
(Automatic
interrupted)
Automatic
interrupted
JOG
Automatic
passive
1)
1)
Deselec-
Deselec-
tion of
tion of
transform.
transform.
Deselection
Deselection
of transform.
of transform.
6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)
09.91

Hide quick links:

Advertisement

Table of Contents
loading