4 Monitoring Functions
4.6 Listing of the alarms/alarm description
3028
Alarm No.
Alarm Text:
"Too many fields/variables"
Remarks:
Alarm only on commissioning
3029
Alarm No.
Alarm Text:
"Graphics option not available"
Reason:
Graphic elements have been projected into the selected display, but
the "Graphics" option is not fitted in the control
Remedy:
– Retrofit "Graphics" option
– Only project display without graphic elements
Explanation:
Only with additional programming developed in WS 800
3030
Alarm-No.
Alarm Text:
"Cursor memory not available"
Reason:
The cursor memory programmed for the display selected is not correct
(number not allowed or too large).
Remedy:
Use the workstation to redefine the cursor memory
Explanation:
– The function of the cursor memory is to position the cursor where it
was previously when the display is called again.
– Only with additional programming via WS 800
3032
Alarm-No.
Alarm Text:
"Too many fields / variables"
Remarks:
Alarm only on commissioning
3033
Alarm-No.
Alarm Text:
"Display text not available"
Reason:
An error has occurred while linking with the workstation.
Remedy:
Check link list, and relink with the workstation (to clear link error).
Explanation:
– Only with additional programming via WS 800
– Alarm only on commissioning
3034
Alarm-No.
Alarm Text:
"Text not available"
Explanation:
– Only with additional programming via WS 800
– Alarm only on commissioning
3040
Alarm-No.
Alarm Text:
"Fields / var. not displayable"
Explanation:
– Only with additional programming via WS 800
– Alarm only on commissioning
3041
Alarm-No.
Alarm Text:
"Too many fields / variables"
Remarks:
Alarm only on commissioning
4-30