Siemens Sinumerik 810T User Manual page 260

Basic version 3, software version 3
Table of Contents

Advertisement

4 Monitoring Functions
4.6 Listing of the alarms/alarm description
2059
Alarm No.
Alarm Text:
"G92 program error"
Reason:
– Use of an invalid address character
– Error on cylindrical interpolation
Remedy:
G92 is only allowed with address "S" (programmed spindle speed
limitation) or "P" (cylindrical interpolation)
2060
Alarm No.
Alarm Text:
"TO, ZO program error"
Reason:
– A non-existent tool offset number was selected
– The value in the selected zero offset or tool offset is too large
2061
Alarm No.
Alarm Text:
"General program error"
Effect:
Inhibiting of NC START
Reason:
– Contour calculation not possible
– Machine data for "axis duplication" function incorrect
2062
Alarm No.
Alarm Text:
"Feed missing/not prog."
Reason:
– No F value programmed
– F value too small (machine data)
– Feed per rev., G95 greater than 50mm/min per revolution
– No feed per rev. programmed
Remedy:
– The axial distance to go for the rotary axis with G98 or G36 is 0 or
no G98 feed has been programmed.
Program correct feed
2063
Alarm No.
Alarm Text:
"Thread lead too high"
Reason:
A thread pitch of more than 400 mm/rev.
(16 inch/rev.) has been programmed.
Effect:
Inhibiting of NC start
Remedy:
Program a smaller thread pitch
4-18
© Siemens AG 1990 All Rights Reserved
01.93
6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)