Power Off Control - Fujitsu Eternus DX60 User Manual

Disk storage system
Hide thumbs Also See for Eternus DX60:
Table of Contents

Advertisement

Chapter 2 Hardware
>
2.2 Standard Operations
2.2.2

Power OFF Control

This section describes the procedure to turn the power off.
IMPORTANT
Procedure
1
2
P3AM-3042-03ENZ0
ETERNUS DX60/DX80 Disk storage system User Guide
When turning off the device, the power shuts off only after the data in the
cache memory has been written to the hard disk. Therefore, it can take
one minute (maximum six minutes) for the power supply to be
completely turned off.
Do not turn off the power of the device or network devices that connect
the ETERNUS DX60/DX80 and server while the server is operating.
Turning the power off may result in the loss of data or prevent data from
being saved.
Press and hold the console panel's power switch ( ) for 4 seconds or longer.
The READY LED should turn off.
Press the power switch only once. If the power switch is pressed
IMPORTANT
again between the time of the READY LED turning off and the
POWER LED turning off, the device power may turn on.
Power switch
The device power is turned off.
When the power is turned off, the POWER LED will go out.
W h e n d r i v e e n c l o s u r e s a r e i n s ta l l e d , t h e p o w e r t u r n s o ff
automatically.
Drive enclosure
Drive enclosure
Controller enclosure
57
End of procedure
Copyright 2009 FUJITSU LIMITED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx80

Table of Contents