Self- Test Health Messages; Displaying Self-Test Results - Paradyne ACCULINK 316x Operator's Manual

Data service unit/channel service unit (includes terminal user interface)
Table of Contents

Advertisement

ACCULINK 316x DSU/CSU
Message
Passed
No problems found during power-up.
CPU fail
Central Processing Unit failed internal testing.
DTE T1 fail
Unit failed to internally loop data on the DTE circuit.
Failure xxxxxxxx
An 8-digit hexadecimal failure code provided for service personnel.
LCD fail
The front panel Liquid Crystal Display (LCD) failed.
Memory fail
Unit failed program checksum verification.
Modem fail
Unit failed to internally loop data through the modem circuit.
NET T1 fail
Unit failed to internally loop data on the network circuit.
Device fail
One or more of the unit's integrated circuit chips failed to pass internal device level testing.
B8ZS/LOS fail
Unit failed to encode data properly or to detect Loss Of Signal.
Alarm fail
Unit failed to transmit AIS or to detect Yellow alarm.
DSU fail
Unit failed to internally loop data on the DSU.
DSU Port n fail
Port's integrated circuit failed to pass device internal testing.
Unknown Exp Dev
Unit unable to recognize the expansion device connected to the main circuit board.

Displaying Self-Test Results

To display power-up self-test results,
1. Press F1 to select Stat from the top-level menu
screen.
DSU ESF
Stat
F1
2. From the Status screen, press F2 to select STest.
Status:
DevHS STest
F1
3-56
Table 3-10
Self-Test Health Messages
Test
Cnfig
F2
F3
Perf
F3
F2
December 1996
Description
3. View the results of the last power-up self-test. If
no problems were found during power-up, the
following message appears.
STest Health:
Passed
F1
F2
F3
3160-A2-GB22-10