Paradyne ACCULINK 316x Operator's Manual page 72

Data service unit/channel service unit (includes terminal user interface)
Table of Contents

Advertisement

ACCULINK 316x DSU/CSU
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
function key. Use the scroll keys, if necessary.
Load from:
Activ
F1
3. Press F1 to select Edit.
Choose Funct:
Edit
F1
4. Press the
key from the Edit screen to display
the SNMP selection.
Edit:
DTE
F1
5. Press F3 to select SNMP.
Edit:
User
F1
6. Press F1 to select Gen from the SNMP Config
screen.
SNMP Config:
Gen
F1
3-30
Cust
Fact1
F2
F3
Save
F2
F3
Port
NET
F3
F2
Alarm
SNMP
F2
F3
Trap
F2
F3
December 1996
7. Press the F1 (Next) key until the
CommunityName1 configuration option appears.
System Name:
Next
Edit
F1
8. Press F2 (Edit) to edit the community name. The
factory default community name is public.
CommunityName1:
Next
Edit
F1
NOTE
Steps 9 and 10 describe the
process for entering text strings
for SNMP configuration options.
This process applies to entering
any text strings into SNMP
configuration options.
9. Use the
and
keys to position the cursor
under the character you want to change. Press F1
(Up) or F2 (Down) to scroll through the valid
numbers/characters for the text string. The valid
characters consist of the set of printable ASCII
characters. The F1 (Up) key scrolls through the
ASCII character set in the following order:
numbers (0–9), lowercase letters (a–z), uppercase
letters (A–Z), space character, ASCII symbols
(ascending order, based on ASCII code), and the
End of Line symbol ( ). The
characters to the right of the cursor.
public
Up
Down
F1
Clear
F2
F3
Clear
F2
F3
erases all
Save
F2
F3
3160-A2-GB22-10