Technical Specifications - Paradyne ACCULINK 316x Operator's Manual

Data service unit/channel service unit (includes terminal user interface)
Table of Contents

Advertisement

The technical specifications for the Models 3160/3164
DSU/CSUs are listed in Table B-1. The technical
specifications for the Model 3161 DSU/CSU are listed in
Table B-2.
ACCULINK Models 3160/3164 DSU/CSUs Technical Specifications
Specifications
POWER REQUIREMENTS
Typical
Options:
+24 Vdc
– 48 Vdc
– 48 Vdc Redundant
POWER CONSUMPTION AND
DISSIPATION
DTE (DSX-1) INTERFACE
Physical Interface
Framing Format
Coding Format
DTE Line Equalization
Send AIS
NETWORK T1 INTERFACE
Physical Interface (USA)
Physical Interface (Canada)
Framing Format
Coding Format
Line Build-Out (LBO)
ANSI PRM
Bit Stuffing
Yellow Alarm Generation
LOOPBACKS
Standard
Additional
PORT INTERFACE
Standards
Rates
3160-A2-GB22-10

Technical Specifications

Table B-1
(1 of 2)
104–132 Vac; 60 Hz 3; 0.15A at 115 Vac for 3160, 0.175A at 115 Vac for 3164
+20 Vdc to +32 Vdc, 0.50A
–38 Vdc to –60 Vdc, 0.25A
–38 Vdc to –60 Vdc, 0.25A
16.0 watts, 55.0 Btu per hour at 115 volts(ac power); 12.0 watts, 41 Btu per hour
at +24 and – 48 Vdc (dc power)
DB15 socket
D4, ESF
AMI, B8ZS
5 selectable ranges from 0 to 655 feet (0 to 196.5 meters)
Selectable
RJ48C
CA81A using adapter cable
D4, ESF
AMI, B8ZS
0.0 dB, –7.5 dB, –15 dB, –22.5 dB
Selectable
FCC Part 68, AT&T TR 62411
Selectable
AT&T TR 54016, AT&T TR 62411, ANSI T1.403.1989
RLB (Repeater Loopback), DLB (DTE Loopback), V.54 Loop 2 and Loop 3,
ANSI T1.403 Annex B Fractional T1 Loopback
EIA 530A, V.35, RS–449, V.11
Nx64 – 64-1.536 Mb
Nx56 – 56-1.344 Mb
December 1996