Configuring The Dsu/Csu; Test Jack Functions; Configuration Option Areas; Configuration Options - Paradyne ACCULINK 316x Operator's Manual

Data service unit/channel service unit (includes terminal user interface)
Table of Contents

Advertisement

ACCULINK 316x DSU/CSU
Test Jack Name
Net In
(Network In)
Net Out
(Network Out)
Net Mon In
(Monitor Network)
Net Mon Out
(Monitor DSX-1)
Eqp Mon Net
(Equipment In)
Eqp Mon Eq
(Equipment Out)

Configuring the DSU/CSU

You have the option of customizing your 316x
DSU/CSU for optimum performance in your network. To
do so, use the DSU/CSU configuration options.
Appendix G contains a set of blank worksheets to use
when configuring your 316x DSU/CSU in the network.

Configuration Option Areas

The 316x DSU/CSU offers four sets of configuration
options located in the following areas:
Active (Activ). The configuration option set active
for the DSU/CSU is stored here. Before a set of
configuration options become active for the
DSU/CSU, you must save the set to the Active area.
When the DSU/CSU is shipped from the factory,
the Active configuration option set is identical to
both the Customer and the Factory 1 sets. This area
can be written to and controls the current operation
of the device.
Customer (Cust). This is the set of
customer-defined configuration options. Customer
set is identical to the Factory 1 set when the
DSU/CSU is shipped from the factory. This area
can be written to.
3-16
Table 3-6

Test Jack Functions

A break-in and test jack that allows a signal to be inserted toward the network by
external test equipment. The signal is inserted on the DSX-1 side of the
DSU/CSU.
A break-in and test jack that interrupts the signal coming from the network and
allows it to be terminated by the external test equipment.
A monitor jack that nonintrusively monitors the incoming signal from the network.
A monitor jack that nonintrusively monitors the incoming signal from the DSX-1.
A break-in and test jack that allows a signal to be inserted toward the DSX-1 by
external test equipment.
A break-in and test jack that interrupts the signal coming from the DSX-1 and
allows it to be terminated by the external test equipment.

Configuration Options

functional groups. Appendix C contains a list of the
configuration options and defaults. These groups are:
December 1996
Function
Factory 1 (Fact1). This is a set of configuration
options preset at the company. This set is
determined by what is considered to be the most
common configuration used in the DSU/CSU
market. Factory 1 options are read-only.
Factory 2 (Fact2). This is a set of configuration
options preset at the company. This set is
determined by what is considered to be the second
most common configuration used in the DSU/CSU
market. Factory 2 options are read-only.
The configuration options are divided into seven
DTE (DSX-1) Interface (see Table C-1)
Port (see Table C-2)
Network Interface (see Table C-3)
Channel (see Tables C-4 and C-5)
General (see Table C-6)
User Interface (see Table C-7)
Alarm (see Table C-8)
General SNMP (see Table C-9)
SNMP Trap (see Table C-10)