Dsx-1 Drop/Insert Port Leds - Paradyne ACCULINK 316x Operator's Manual

Data service unit/channel service unit (includes terminal user interface)
Table of Contents

Advertisement

Name
Color
SIG
Green
OOF
Yellow
ALRM
Yellow
PDV
Yellow
BPV
Yellow
3160-A2-GB22-10
Table 3-3

DSX-1 Drop/Insert Port LEDs

Monitors the signal being received from the DSX-1.
ON :
A recoverable signal is being received from the DSX-1.
OFF :
The signal cannot be recovered from the DSX-1 (a Loss of Signal
condition exists).
Monitors Out Of Frame (OOF) conditions on the received DSX-1 signal.
ON :
At least one OOF was detected on the signal during the sampling
period.
OFF :
No OOFs were detected on the signal during the sampling period.
Indicates whether an alarm condition exists on the received DSX-1 signal.
ON :
An alarm condition (LOS, LOF, EER, Yellow, AIS) exists on the received
DSX-1 signal. Use the Device Health and Status command to determine
the alarm type.
OFF :
No alarm condition exists on the DSX-1 Interface signal.
Monitors Pulse Density Violations (PDV) on the received DSX-1 signal.
ON :
At least one PDV was detected (and corrected) on the received DSX-1
signal during the sampling period.
OFF :
No PDVs were detected on the received DSX-1 signal during the
sampling period.
Monitors DSX-1 Bipolar Violations (BPV) on the received DSX-1 signal.
ON :
At least one BPV was detected (and corrected) on the received DSX-1
signal during the sampling period.
OFF :
No BPVs were detected on the received DSX-1 signal during the
sampling period.
December 1996
Meaning
Operation
3-9