Selecting the Number of Trap Managers

If you intend to issue traps to an SNMP manager(s)
from this device, you must specify the number of SNMP
managers that are to receive the traps.
To specify the number of SNMP managers to receive
traps from this device,
1. Press F3 to select Cnfig from the top-level menu
screen.
DSU ESF
Stat
F1
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
function key. Use the scroll keys, if necessary.
Load from:
Activ
F1
3. Press F1 to select Edit.
Choose Funct:
Edit
F1
3-32
Test
Cnfig
F2
F3
Cust
Fact1
F3
F2
Save
F2
F3
December 1996
4. Press the
key from the Edit screen to display
the SNMP selection.
Edit:
DTE
F1
5. Press F3 to select SNMP.
Edit:
User
F1
6. Press F2 to select Trap from the SNMP Config
screen.
SNMP Config:
Gen
F1
7. Select the number of SNMP managers to receive
traps (from 1 through 6) by using the appropriate
function key. Use the scroll keys, if necessary.
Num Trap Mgrs:1
Next
F1
Differences Using the Async Terminal: To set the
number of trap managers, select Trap Options from the
main/configuration/edit/snmp menu. Figure 3-23 shows
an example of the screen that appears.
Port
NET
F2
F3
Alarm
SNMP
F3
F2
Trap
F3
F2
1
2
F2
F3
3160-A2-GB22-10