ACCULINK 316x DSU/CSU
Context-Sensitive Menu
This DSU/CSU is an intelligent device that displays
only those options that are valid for the current
configuration. Therefore, you will only be presented with
menu choices that are consistent with the current
configuration and operational state of the DSU/CSU;
invalid combinations of configuration options are not
displayed. Although all options are shown in this manual,
what you see on your DSU/CSU varies with your
configuration.
DTE Port: Enab
Next
Enab
Disab
Prev
DTE Drop/Insert T1 Port. Enables the use of the DTE Drop/Insert port.
Enab – Allows the use of the DSX-1 Drop/Insert T1 interface.
Disab – Prohibits the use of the DSX-1 Drop/Insert T1 interface.
NOTE: When this configuration option is disabled, you cannot display or configure any other DTE Interface configuration
options.
DTE Framing: ESF (Factory 1)
Next
D4
ESF
Prev
DTE Line Framing Format. Designates the framing format for the DTE T1 interface.
D4 – Configures for the D4 framing format.
ESF – Configures for the Extended Superframe framing format.
DTE Coding: B8ZS (Factory 1)
Next
AMI
B8ZS
Prev
DTE Line Coding. Designates the line coding format to be used on the DTE interface.
AMI – Uses the Alternate Mark Inversion coding format.
B8ZS – Uses the Bipolar 8 Zero Suppression coding format.
Equal: 0—133
Next
0—133
133—266
DTE Line Equalization. Specifies the DTE line equalization compensation parameters which permit a standard DSX
signal to be delivered over a distance of up to 655 feet.
C-2
Table C-1
(1 of 2)
DTE Interface Configuration Options
D4 (Factory 2)
AMI (Factory 2)
266—399
399—533
533—655
December 1996
DTE Interface Configuration
Options
Prev