Paradyne ACCULINK 316x Operator's Manual page 194

Data service unit/channel service unit (includes terminal user interface)
Table of Contents

Advertisement

ACCULINK 316x DSU/CSU
testMonQRSS – Initiates a Monitor QRSS test on
the interface. Supported for the data ports and the
Network T1 interface.
testMon511 – Initiates a Monitor 511 test on the
interface. Only supported for the data ports.
testSendQRSS – Initiates a Send QRSS test on the
interface. Only supported for the data ports.
testSend511 – Initiates a send 511 test on the
interface. Only supported for the data ports.
testSendV54Up – Sends a V54 up code to the
remote unit. Only supported for the data ports.
testSendV54Down –Sends a V54 down code to the
remote unit. Only supported for the data ports.
testSendFT1Up – ends a FT1 up code to the remote
unit. Only supported for the data ports.
testSendFT1Down – Sends a FT1 down code to the
remote unit. Only supported for the data ports.
Where these object identifiers are defined as follows:
testLoopDTLB – OBJECT IDENTIFIER ::=
[wellKnownTests 2]
testMonQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 3]
testMon511 – OBJECT IDENTIFIER ::=
[wellKnownTests 4]
testSendQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 5]
testSend511 – OBJECT IDENTIFIER ::=
[wellKnownTests 6]
testSendV54Up – OBJECT IDENTIFIER ::=
[wellKnownTests 7]
testSendV54Down – OBJECT IDENTIFIER ::=
[wellKnownTests 8]
testSendFT1Up – OBJECT IDENTIFIER ::=
[wellKnownTests 9]
testSendFT1Down – OBJECT IDENTIFIER ::=
[wellKnownTests 10]
E-14
Generic Interface Test Table –
"ifExtnsTestResult" Object
(ifExtnsTestEntry 5)
This object contains the result of the most recently
requested test. Only the following values are supported by
the DSU/CSU.
none(1) – No test currently active.
inProgress(3) – A test is currently in progress.
notSupported(4) – The requested test is not
supported.
unAbleToRun(5) – The requested test cannot run
due to the state of the unit.
Generic Interface Test Table –
"ifExtnsTestCode" Object
(ifExtnsTestEntry 6)
This object contains a code which contains more
specific information on the test result. This object is
defined as an INTEGER. Only the following values are
supported by the DSU/CSU.
none – No further information is available. Used for
the send pattern/code and loopback tests.
inSyncNoBitErrors – A monitor pattern (QRSS or
511) test has synchronized on the pattern and has
not detected any bit errors.
inSyncWithBitErrors – A monitor pattern (QRSS or
511) test has synchronized on the pattern and has
detected bit errors.
notInSync – A monitor pattern (QRSS or 511) test
has not synchronized on the requested pattern.
Where these object identifiers are defined as follows:
wellKnownCodes – OBJECT IDENTIFIER ::=
[ifExtensions 5]
none – OBJECT IDENTIFIER ::=
[wellKnownCodes 1]
inSyncNoBitErrors – OBJECT IDENTIFIER ::=
[wellKnownCodes 2]
inSyncWithBitErrors – OBJECT IDENTIFIER ::=
[wellKnownCodes 3]
notInSync – OBJECT IDENTIFIER ::=
[wellKnownCodes 4]
December 1996
3160-A2-GB22-10

Advertisement

Table of Contents
loading

Table of Contents