Paradyne ACCULINK 316x Operator's Manual page 162

Data service unit/channel service unit (includes terminal user interface)
Table of Contents

Advertisement

Access 2: Read
Next
Read
R/W
Prev
Access 2. Specifies the type of access allowed for community name 2. This is the type of access allowed for external
SNMP managers accessing objects in the MIB using community name 2.
Read – Allows read-only access (SNMP Get) to the accessible objects in the MIB for this device when community
name 2 is used. This includes all objects specified as either read-only or read/write in the MIB RFCs.
R/W – Allows read and write access (SNMP Get and Set) to the objects in the MIB for this device when community
name 2 is used. Write access is allowed for all objects specified as read/write in the MIB RFCs. Read access is allowed
for all objects specified as either read-only or read/write.
Com IP Adr: Clear
Next
Edit
Clear
Prev
Com Port IP Address. Specifies the IP address for the COM port of the 316x Series device when it is configured as the
SNMP management link. The IP address is only in effect when the Com Use configuration option is set to SNMP.
Edit – Allows you to edit or display the IP address for the communication port using the generic IP address data entry
screen.
Clear – Allows you to clear the IP address for the communication port.
Com Link: PPP
Next
PPP
SLIP
Prev
Com Port Link Layer Protocol. Specifies the link layer protocol for the COM port when it is configured as the SNMP
management link. This protocol is only in effect when the Com Use configuration option is set to SNMP.
PPP – Specifies the PPP as the link layer protocol for the SNMP management link on the communication port.
SLIP – Specifies SLIP as the link layer protocol for the SNMP management link on the communication port. The
communication port must be configured for asynchronous operation to support SLIP.
Modem IP Adr: Clear
Next
Edit
Clear
Prev
Modem Port IP Address. Specifies the IP address for the MODEM port of the 316x Series device when it is configured for
SNMP. This IP address is only in effect when the Modem Use configuration option is set to SNMP.
Edit – Allows you to edit or display the IP address for the modem port using the generic IP address data entry screen.
Clear – Allows you to clear the IP address for the MODEM port.
Alt Mdm IP Adr: Clear
Next
Edit
Clear
Prev
Alternate Modem Port IP Address. Specifies the alternate IP address for the MODEM port of the 316x Series device when
it is configured for SNMP. This IP address is needed when a call attempt does not complete on the primary alarm/trap
phone number (contained in the alarm directory) and the alternate dial out directory is used to try another phone number.
Edit – Allows you to edit or display the alternate IP address for the MODEM port using the generic IP address data entry
screen.
Clear – Allows you to clear the alternate IP address for the MODEM port.
Modem Link: PPP
Next
PPP
SLIP
Prev
Modem Port Link Layer Protocol. Specifies the link layer protocol for the MODEM port when it is configured as the SNMP
management link. This protocol is only in effect when the Modem Use configuration option is set to SNMP.
PPP – Specifies PPP as the link layer protocol for the SNMP management link on the MODEM port.
SLIP – Specifies SLIP protocol as the link layer protocol for the SNMP management link on the MODEM port. The
MODEM port must be configured for asynchronous operation to support SLIP.
3160-A2-GB22-10
Table C-9
(2 of 2)
General SNMP Configuration Options
December 1996
Configuration Options
C-21