Hitachi XP P9500 User Manual page 277

Hitachi dynamic link manager software user guide for windows (6.6) (hit5201-96006, november 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

#1
Key name
Specify, in minutes, the interval at
path_health_chec
which the path health check will be
k_interval
performed.
You can specify a value from 1 to
1440. The default is 30.
Specify whether to enable
auto_failback
automatic failbacks for failed paths
by specifying either of the
following values:
on: Enable automatic failback
(default).
off: Disable automatic failback.
Specify, in minutes, the path
auto_failback_in
status check interval, which is the
terval
interval between the end of the
previous check and the start of the
next check.
You can specify a value from 1 to
1440. The default is 1.
Specify whether to enable
intermittent_err
#4 #5
intermittent error monitoring by
or_monitor
specifying either of the following
values:
on: Enable intermittent error
monitoring.
off: Disable intermittent error
monitoring (default).
Specify, in minutes, the
intermittent_err
intermittent error monitoring
or_monitor_inter
interval.
#5
val
You can specify a value from 1 to
1440. The default is 30.
Specify how many times an error
intermittent_err
needs to occur to cause HDLM to
or_monitor_numbe
assume an intermittent error.
#5
r
You can specify a value from 1 to
99. The default is 3.
Specify whether to enable the LU
remove_lu
dynamic removal function by
setting either of the following
values:
Hitachi Dynamic Link Manager User Guide (for Windows(R))
#2
Description
Utility Reference
Necessity of
definition
Maximu
Upgrade
charact
installat
New
ion or
installat
length
Re-
ion
installat
ion
Optional
Optional
4
Optional
Optional
3
Optional
Optional
4
Optional
Optional
3
Optional
Optional
4
Optional
Optional
2
Optional
Optional
3
m
er
#
3
7-23