Hitachi XP P9500 User Manual page 101

Hitachi dynamic link manager software user guide for windows (6.6) (hit5201-96006, november 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

10
Specify the installation folder by following the instructions shown in the
.
messages that appear in the window.
The utility for registering HDLM persistent reservation keys (dlmprsvkey)
will be automatically executed. However, creation of the PRSV key might
be unsuccessful if, for example, an NIC does not exist. If the PRSV key is
created with time information only, or if key creation fails, a dialog box
will prompt you to enter the PRSV key.
If this dialog box appears, go to step 10; otherwise, go to step 12.
11
Enter the PRSV key by following the instructions shown in the dialog box.
.
The PRSV key is required for the HDLM functions to properly operate.
Also, the value of the PRSV key must be unique for each host.
12
If the KAPL09128-W message appears, you will need to re-enter a correct
.
PRSV key.
If a message does not appear, go to the next step.
13
Select an HDLM management-target device only when the OS is one of
.
the following:
Windows Server 2003 (x86) SP1 or later
¢
Windows Server 2003 (IPF) SP1 or later
¢
Windows Server 2003 (x64)
¢
#
This OS cannot be used with the EMC DMX series.
The Hitachi storage systems and HP StorageWorks XP Series option
is always selected. To select an EMC DMX series or EMC CX series LU as
the HDLM management-target device, select EMC Symmetrix DMX
Series, CLARiiON CX Series. To select an HP EVA series LU as the
HDLM management-target device, select HP StorageWorks EVA Series.
14
Follow the instructions shown in the messages that appear in the window.
.
If a dialog box with the following text appears during installation, and
¢
the Storport Miniport driver is being used as the HBA driver, stop the
HDLM installation. After that, install QFE838894 or a later version of
the Microsoft Storport driver, or install Windows Server 2003 SP1 or
later.
Notes on using a Storport Miniport driver
Read these notes before using a Storport Miniport driver as an
HBA driver.
The file version of the Storport.sys of this system
(Microsoft(R) Storport driver) is n.n.nnnn.n.
When using a Storport Miniport driver as an HBA driver:
Please update the Storport Miniport driver to a Storport.sys
with a file version n.n.nnnn.n or later.
The PRSV key will be registered before the installation finishes. If the
¢
KAPL09131-W message appears, follow the procedure described in
step 15.
Although a message prompting you to restart the host appears after
¢
the installation has finished, a restart is not necessary.
Creating an HDLM Environment
Hitachi Dynamic Link Manager User Guide (for Windows(R))
#
3-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynamic link manager

Table of Contents