Number of
messages to be
output per
monitoring
interval
If Hitachi Network Objectplaza Trace Library (HNTRLib2) is already installed,
the existing settings will be inherited. If you change these settings, keep in
mind that programs other than HDLM also use them. If an earlier Hitachi
Network Objectplaza Trace Library (HNTRLib) is already installed, the settings
will not be inherited.
To change the integrated trace file settings:
1
In Explorer, double-click the following file:
.
program-installation-destination-drive:\Program Files
\HNTRLib2\bin\hntr2utl2.exe
If you are using the Server Core environment of Windows Server 2008,
execute hntr2utl2.exe from the Administrator: Command Prompt
window.
#
The Hitachi Network Objectplaza Trace Utility 2 Release 2.0 dialog box
shown in
2.0 Dialog Box. on page 3-81
3-80
Setting
Buffer size per
monitoring interval
Monitoring cycle
Number of messages
to be output
For Windows Server 2003 (excluding the x86 edition) or Windows
Server 2008 (excluding the x86 edition), Program Files is Program
Files (x86).
Figure 3-5 Hitachi Network Objectplaza Trace Utility 2 Release
Creating an HDLM Environment
Hitachi Dynamic Link Manager User Guide (for Windows(R))
Default value
64 (KB)
0 (seconds)
0
appears.
Recommended
value
256 (KB)
0 (seconds)
0
#
\HITACHI