Hitachi XP P9500 User Manual page 252

Hitachi dynamic link manager software user guide for windows (6.6) (hit5201-96006, november 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

summary
displayed
-
-
Legend:
- : Not displayed
#1
This information is displayed when one of the following conditions exist:
- The user selected the item to be displayed by using the -lu -item
parameter.
- all was specified.
- No value was specified for the parameter.
#2
This information is displayed when one of the following conditions exist:
- The user selected the item to be displayed by using the -lu -c -item
parameter.
- No value was specified for the parameter.
#3
The drive letter assigned to a dynamic disk volume is not displayed.
#4
In a cluster configuration, an offline operation requested during reserve
processing is put into the waiting-to-execute state, and does not execute
until the reserve processing finishes.
6-64
Displayed item
No
Summary
displayed
Paths
OnlinePaths
Command Reference
Hitachi Dynamic Link Manager User Guide (for Windows(R))
Description
-: Indicates that intermittent error monitoring is
disabled or the monitoring time for an
intermittent error is out of range.
A value of at least 0: Indicates the number of
errors that occurred during intermittent error
monitoring.
*: Indicates that an intermittent error occurred
(automatic failback does not check the path).
Total number of the paths recognized by HDLM for
the LU to be displayed.
Number of online paths among the paths recognized
by HDLM for the LU. When the value of Paths is
equal to the value of OnlinePaths, all paths are
online. If the value of OnlinePaths is less than that
of Paths, some paths may have an error status, in
which case you should check the status of individual
paths and take resolve the problem for any paths
that have an error status.