Installing The Pci Riser-Card Assembly; Removing And Installing The Hot-Swap Sas/Sata Hard Disk Drive Backplane - Lenovo ThinkServer RD210 Hardware Maintenance Manual

Hardware maintenance manual
Hide thumbs Also See for ThinkServer RD210:
Table of Contents

Advertisement

1
PCI riser-card assembly (full-height, full-length adapters)
2
PCI riser-card assembly (low-profile adapters)
3
PCI riser connector 1
4
PCI riser connector 2
6. Remove the adapter, if one is present, from the riser-card assembly.
7. Set the adapter and riser-card assembly aside.

Installing the PCI riser-card assembly

To replace a PCI riser-card assembly, complete the following steps:
1. Read the safety information in Chapter 2 "Safety information" on page 3 and "Installation guidelines"
on page 67.
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables.
3. Remove the cover (see "Removing and replacing the cover" on page 72).
4. Install the adapter in the new PCI riser-card assembly (see "Removing and installing a PCI riser-card
assembly" on page 81).
5. Set any jumpers or switches on the adapter as directed by the adapter manufacturer.
6. Align the PCI riser-card assembly with the PCI slot connector on the system board: then, press down
firmly until the riser-card assembly in seated correctly in the connector on the system board.
1
PCI riser-card assembly (full-height, full-length adapters)
2
PCI riser-card assembly (low-profile adapters)
3
PCI riser connector 1
4
PCI riser connector 2
Removing and installing the hot-swap SAS/SATA hard disk drive
backplane
To remove and install the hot-swap SAS/SATA hard disk drive backplane, complete the steps in this section.
.
Chapter 7
Installing optional devices and replacing customer replaceable units
107