Windows NT®4.0 Installation
(the disk on the lower channel number) being copied to the other
drive. In RAID 10 arrays, data from one half of the array is copied
to the other half. After the initial verification, subsequent verifies to
a RAID 1 or 10 array result in the data from one drive (or set of
drives) being compared to the other drive (or set of drives).
RAID 5 arrays are immediately initialized after being created in the
BIOS by writing zeroes to all array members. The user can reboot
the system before this is complete in order to use the RAID 5 array
immediately. Once booted to the operating system, the RAID 5
array goes into initialization mode after a delay of up to ten min-
utes. The advantage of this procedure is that the RAID 5 array can
be used immediately, but it will not be fault tolerant until the initial-
ization is complete. The disadvantage of this is that it takes longer
for the array to become fully redundant, because it takes longer to
initialize an array than it does to write zeroes to the array.
Install the 3DM disk management utility
Refer to the 3DM Disk Management Utility chapter.
www.3ware.com
73
Need help?
Do you have a question about the 7000-2 - Escalade RAID Controller and is the answer not in the manual?