Table 30
Element Manager messages (continued)
Message
Stop diagnostics failed.
The test is already
running.
Stop diagnostics failed.
The test was not running.
Switch Binding was
removed from attached
devices that are also
participating in Port
Binding. Please review
the Port Binding
Configuration.
System diagnostics
cannot run. The
Operational Status is
invalid.
The add firmware process
has been aborted.
Switch clock alert mode
must be cleared before
enabling period
synchronization.
The data collection
process failed.
256
Informational and error messages
Description
Diagnostics for the port
was not running and Stop
was selected on the Port
Diagnostics dialog box.
Diagnostics quit for the
port for some reason, but
the Stop button remains
enabled.
This action failed because
the test was not running.
The device WWNs were
removed from the
director's Switch
Membership List
(SANtegrity Binding
feature), but you should
note that one or more of
these devices still has
security control in Port
Binding.
System diagnostics
cannot run on switches
with failed ports
You aborted the process
to add a firmware version
to the HAFM appliance's
firmware library.
Clock alert mode is
enabled through the
Configure FICON
Management Server
dialog box and user is
attempting to enable
Periodic Date/Time
Synchronization through
the Configure Date and
Time dialog box.
An error occurred while
performing the data
collection procedure.
Action
Verify port operation. Retry
diagnostics for the port and choose
Stop from the dialog box. If
problem persists, contact the next
level of support.
Informational message.
Verify that the security level for
each device is as required by
reviewing the Bound WWN list in
the Configure Ports dialog box.
Replace failed ports.
Verify the firmware addition is to
be aborted, then click OK to
continue.
Disable clock alert mode through
the Configure FICON
Management Server dialog box.
Try the data collection procedure
again. If the problem persists,
contact the next level of support.