Table 30
Element Manager messages (continued)
Message
Cannot enable
beaconing while the
system light is on.
Cannot enable
beaconing while the
system error light is on.
Cannot enable Open
Trunking while Enterprise
Fabric Mode is active and
the switch is offline.
Cannot have E-Ports if
Management Style is
FICON unless SANtegrity
feature is installed. Please
contact your sales
representative.
Cannot have spaces in
field.
Cannot install firmware to
a director with a failed
CTP card.
Description
Occurs when choosing
Enable Beaconing option
for a failed FRU.
Beaconing cannot be
enabled while the system
error light is on.
Enterprise Fabric mode is
active and the switch or
director is online and you
attempted to enable
Open Trunking. This
message is displayed if
the optional Open
Trunking feature is
installed.
Firmware is below the
required level and you
attempted to change
management style from
Open Systems to FICON
management style with
E_Ports configured, but
SANtegrity Binding is not
installed.
Spaces are not allowed
as part of the entry for
this field.
A firmware version
cannot be installed on a
director with a failed
control processor (CTP)
card.
Action
Replace FRU and enable
beaconing again or enable
beaconing on an operating FRU.
Select Clear System Error Light
from Product menu to clear error
light, then enable beaconing.
Perform either of the following
steps:
Disable Enterprise Fabric Mode
option by selecting the appropriate
fabric in the Fabric Tree portion of
the HAFM Manager window
(Fabrics tab) and then selecting
Enterprise Fabric Mode from the
Fabrics menu. When the Enterprise
Fabric Mode dialog box is
displayed, click Start and follow
prompts to disable the feature.
Set the switch or director offline
through the Set Online State dialog
box. Display this dialog box by
selecting Set Online State from the
Element Manager Maintenance
menu.
Informational message. If firmware
is below the required level and you
install SANtegrity Binding before
changing to FICON management
style, then E_Ports will remain as
E_Ports when you change to
FICON management style. If
SANtegrity Binding is not installed,
setting a director to FICON
management style will change all
E_Ports to G_Ports.
Delete spaces from the field entry.
Replace the failed CTP card and
retry the firmware installation.