Table 30
Element Manager messages (continued)
Message
Port numbers must be in
the range of 0 to xxx.
Preferred Paths can not be
enabled until the Domain
ID is set to Insistent.
Disable Preferred Paths,
then configure Switch
Parameters.
R_A_TOV must be greater
than E_D_TOV.
Resource is unavailable.
Resource is unavailable.
SANtegrity Feature not
installed. Please contact
your sales representative.
Send firmware failed.
SNMP trap address not
defined.
Description
When configuring
Preferred Paths, source
ports and exit ports must
be in the range of ports
for the switch being
configured.
If the switch's domain ID
has not been set to
Insistent, the user is not
allowed to activate the
Preferred Path
configuration with the
Enable Preferred Paths
check box selected.
R_A_TOV must be greater
than E_D_TOV.
The specified operation
cannot be performed
because the product is
unavailable.
The specified operation
cannot be performed
because the product is
unavailable.
You selected Switch
Binding from the
Configure menu, but the
optional SANtegrity
Binding feature is not
installed.
A firmware download
operation failed.
If an SNMP community
name is defined, a
corresponding SNMP
trap recipient address
must also be defined.
Action
In the Configure Preferred Paths
dialog box, change the numbers in
the Source Port and Exit Port fields
to fall within the port count of the
switch on which you are
configuring paths.
Close the Configure Preferred Paths
dialog box and select Configure >
Operating Parameters > Switch
Parameters. In the Configure
Switch Parameters dialog box, click
the Insistent check box.
Change one of the values so that
R_A_TOV is greater than E_D_TOV
Verify that the Ethernet connection
between the HAFM appliance and
the director is up or available.
Verify that the HAFM
appliance-to-product link is up. If
the link is up, the HAFM appliance
can be busy. Try the operation
again later.
Install the SANtegrity Binding key
through the Configure Feature Key
dialog box before using Switch
Binding features.
Retry the firmware download
operation. If the problem persists,
contact the next level of support.
Enter a corresponding SNMP trap
recipient address.