Control VLAN
RM Node periodically sends "RM Test Packet" message to detect the loop. RM Test
packet message can be transmiited by control VLAN only. Each ERP domain should have
one control VLAN.
To configure a control VLAN of an ERP domain, use the following command.
Command
control-vlan VLAN
no control-vlan
ERP Ring Priority
The Super Loop occurs because of a shared link's failure between two ERP rings. A do-
main with higher priority (one of the RM nodes) is the only responsible for monitoring the
ports of a shared link. The control packets of a domain with lower ring priority can be
transmitted to another domain with higher priority to prevent the super loop.
It means that the higher ring priority domain guarantees the detour path against a shared
link of lower ring priority domain.
To specify ERP ring priority, use the following command.
Command
ring-priority <1-255>
To return ERP ring priority as default, use the following command.
Command
no ring-priority
Displaying ERP Domian
To display a configuration for specific ERP domain, use the following command.
Command
show pending
show current
show
Mode
Configures a control VLAN of ERP domain.
ERP
Domain
Deletes configured control VLAN of ERP domain
Mode
ERP
Specifies ERP ring priority
Domain
1-255: ERP ring priority value (default: 0)
Mode
ERP
Configures ERP ring priority as default value
Domain
Mode
Shows modified configurations of ERP domain.
ERP
Shows updated configuration of ERP domain.
Domain
Shows all of configuration of ERP domain.
Description
Description
Description
Description
CLI
295