CLI
7.1.9.5
146
ADVA Alarm Severity
To set ADVA alarm severity, use the following command.
Command
snmp alarm-severity adva-fan-fail {critical |
major | minor | warning | intermediate}
snmp alarm-severity adva-if-misconfig {critical
| major | minor | warning | intermediate}
snmp alarm-severity adva-if-opt-thres {critical |
major | minor | warning | intermediate}
snmp alarm-severity adva-if-rcv-fail {critical |
major | minor | warning | intermediate}
snmp alarm-severity adva-if-trans-fault {criti-
cal | major | minor | warning | intermediate}
snmp
alarm-severity
{critical | major | minor | warning | intermedi-
ate}
snmp alarm-severity adva-psu-fail {critical |
major | minor | warning | intermediate}
snmp alarm-severity adva-temperature {critical
| major | minor | warning | intermediate}
snmp alarm-severity adva-voltage-high {criti-
cal | major | minor | warning | intermediate}
snmp alarm-severity adva-voltage-low {critical
| major | minor | warning | intermediate}
To delete configured ADVA alarm severity, use the following command.
Command
no snmp alarm-severity adva-fan-fail
no snmp alarm-severity adva-if-misconfig
no snmp alarm-severity adva-if-opt-thres
no snmp alarm-severity adva-if-rcv-fail
no snmp alarm-severity adva-if-sfp-mismatch
no snmp alarm-severity adva-if-trans-fault
no snmp alarm-severity adva-psu-fail
no snmp alarm-severity adva-temperature
no snmp alarm-severity adva-voltage-high
no snmp alarm-severity adva-voltage-low
adva-if-sfp-mismatch
Mode
Description
Sets ADVA severity of an alarm for sys-
tem temperature high.
Sets ADVA severity of an alarm for
wrong configuration.
Sets ADVA severity of an alarm for traf-
fic threshold over for an Ethernet optical
interface.
Sets ADVA severity of an alarm for fail-
ure to receive packets.
Sets ADVA severity of an alarm for fail-
ure to transmit packets.
Global
Sets ADVA severity of an alarm for SFP
module mismatched.
Sets ADVA severity of an alarm for PSU
failure.
Sets ADVA severity of an alarm for sys-
tem temperature high.
Sets ADVA severity of an alarm for input
voltage high.
Sets ADVA severity of an alarm for input
voltage low.
Mode
Description
Deletes configured ADVA alarm sever-
Global
ity.
Management Guide
TigerAccess™ EE
SMC7824M/VSW