SMC7824M/VSW
To enable Interleave process, use the following command.
Command
lre PORTS channel slow
The default is Interleave enabled as "slow".
The following is an example of displaying Interleave.
SWITCH(bridge)# show lre interleave 1-5
------------------------------------------
Port Status
Channel
ADM/OPR
------------------------------------------
1
Up/Down
2
Up/Down
3
Up/Down
4
Up/Down
5
Up/Down
SWITCH(bridge)#
In addition, you can configure the interval of Interleave process during modulation. This
interval is called Interleave-delay. By configuring Interleave-delay, you can prevent trans-
mission delay caused of waiting data gathered.
To configure Interleave-delay, use the following command.
Command
lre PORTS interleave-delay
<1-100>
lre PORTS interleave-delay
<1-100> {upㅣdown}
The unit of Interleave-delay is "㎳" and the default is "2ms".
In switch, all VDSL ports are contained in one Line-config-profile. For the ports contained
as the member port of Line-config-profile, it is not possible to change Interleave-delay or
SNR margin.
To change it independently, erase the member of Line-config-profile first refer to
Line config
profile. If you try to configure interleave-delay of the port which is contained as
Line-config-profile member, the error message will be displayed.
Mode
Bridge
Inter-Delay
UP/DOWN
Slow
2/ 2
Slow
2/ 2
Slow
2/ 2
Slow
2/ 2
Slow
2/ 2
Mode
Bridge
Description
Enables Interleave process.
Description
Configures Interleave-delay
PORTS: VDSL port number
1-100: interleave delay value (default:2 ms)
Configures Interleave-delay with specifying Upstream
or Downstream.
CLI
5.3.4.1