Danfoss VLT FC 280 Operating Manual page 108

Midi drive with profisafe
Hide thumbs Also See for VLT FC 280:

Advertisement

Operating Guide | VLT® Midi Drive FC 280
Application Examples
7
Introduction
7.1
The examples in this section are intended as a quick reference for common applications.
Parameter settings are the regional default values unless otherwise indicated (selected in parameter 0-03 Regional Settings).
l
Parameters associated with the terminals and their settings are shown next to the drawings.
l
Required switch settings for analog terminals 53 or 54 are also shown.
l
AMA
7.2
Table 50: AMA with T27 Connected
FC
+24 V
12
+24 V
13
D IN
18
D IN
27
D IN
32
33
D IN
+10 V
50
A IN
53
COM
55
Speed
7.3
Table 51: Analog Speed Reference (Voltage)
108
| Danfoss A/S © 2024.10
Parameters
Function
Parameter 1-29 Automatic Motor
Adaptation (AMA)
Parameter 5-12 Terminal 27 Digital Input
*=Default value
Notes/comments:
Set parameter group 1-2* Motor Data according to motor specifications.
If terminals 13 and 27 are not connected, set parameter 5-12 Terminal 27 Digital
Input to [0] No operation.
Parameters
Function
Parameter 6-10 Terminal 53 Low Voltage
Parameter 6-11 Terminal 53 High Voltage
Parameter 6-14 Terminal 53 Low Ref./Feedb. Value
Parameter 6-15 Terminal 53 High Ref./Feedb. Value
Parameter 6-19 Terminal 53 mode
*=Default value
Notes/comments:
Application Examples
Setting
[1] Enable complete AMA
*[2] Coast inverse
  NOTICE
AQ381425076031en-000201 / 130R1223
Setting
*0.07 V
*10 V
0
50
[1] Voltage