Operating Guide | VLT® Midi Drive FC 280
Transferring the Firmware Information
5.10.5
If 2 drives are of same voltage and power size, the firmware information can be transferred from 1 drive to another.
The firmware information can also be downloaded to the memory module from a PC via the VLT® Memory Module Programmer.
1.
Follow the steps in
5.10.2 Synchronizing Drive Data to a New Memory Module (Create Drive Backup)
information from 1 drive to a memory module.
2.
Follow the steps in
5.10.3 Copying Data to Another Drive
and power size.
5.10.6
Backing Up Parameter Changes to Memory Module
1.
Plug a new empty memory module in the drive.
2.
Select [2] Only Allow Upload or [3] Allow Both Download and Upload in parameter 31-40 Memory Module Function.
3.
Power up the drive.
4.
Wait until the synchronization is complete. Refer to
on the drive.
5.
Any change to parameter settings is automatically synchronized to the memory module.

Erasing Data

5.10.7
The memory module can be erased via setting parameter 31-43 Erase_MM without a new power cycle.
1.
Make sure that the memory module is mounted in the drive.
2.
Select [1] Erase MM in parameter 31-43 Erase_MM.
3.
All files in the memory module are erased.
4.
Parameter 31-43 Erase_MMsetting returns to [0] No function.

Transfer Performance and Indications

5.10.8
The time for transferring different data between the drive and the memory module is different, refer to the following table.
Table 21: Transfer Performance
Data file
Time
Firmware file
• It takes around 2 minutes for uploading data from the drive to the memory module.
• It takes around 6 minutes for downloading data from the memory module to the drive.
SIVP file
Around 10 s.
(1)
Parameter file
Around 5 s.
1) If a parameter is changed in the drive, to upload the updated parameter, wait at least 5 s before power-down.
56
| Danfoss A/S © 2024.10
  NOTICE
to transfer the firmware information to another drive of same voltage
5.10.8 Transfer Performance and Indications
Commissioning
to upload the firmware
to check the transfer indications
AQ381425076031en-000201 / 130R1223