Alert Group Trigger Events and Commands
Table 7-3
Call Home Alert Groups, Events, and Actions (continued)
Call Home
Alert Group
Trigger Event
—
—
—
—
—
—
—
—
—
—
—
ENVM
—
—
Inventory
—
—
SPA
HARDWARE_
REMOVAL
—
SPA
HARDWARE_I
NSERTION
—
CC/FP/RP
HARDWARE_
REMOVAL
—
CC/FP/RP
HARDWARE_I
NSERTION
Cisco ASR 1000 Series Aggregation Services Routers Software Configuration Guide
7-38
Syslog Event
%ASR1000_PEM-3-FANFAIL
%ASR1000_PEM-6-FANOK
%ASR1000_PEM-3-PEMFAIL
%ASR1000_PEM-6-PEMOK
%ENVIRONMENTAL-1-ALERT
%ENVIRONMENTAL-1-SENSORFAIL 1
%ENVIRONMENTAL-1-SENSOROK
—
%ASR1000_OIR-6-REMSPA
%ASR1000_OIR-6-INSSPA
%ASR1000_OIR-6-REMCARD
%ASR1000_OIR-6-INSCARD
Chapter 7
Description and CLI Commands
Severity
Executed
3
The fan in slot (slot/subslot
number) is encountering a failure
condition.
6
The fan in slot (slot/subslot
number) is functioning properly.
3
The PEM in slot (slot number) is
switched off or encountering a
failure condition.
6
The PEM in slot (slot number) is
functioning properly.
1
Any sensor in fp/cc/rp has exceeded
a certain threshold and resulted in
this environmental alert.
Any sensor in fp/cc/rp has failed
and resulted in this environmental
alert.
1
Any sensor in fp/cc/rp has
recovered and resulted in this
environmental alert.
—
Inventory status should be provided
whenever a unit is cold-booted, or
when FRUs are inserted or
removed. This is considered a
noncritical event, and the
information is used for status and
entitlement. (Sent to TAC.)
CLI commands executed:
show platform
show inventory oid
show version
show diag all eeprom detail
6
SPA removed from subslot
(slot/subslot number) and the
interfaces are disabled.
6
SPA inserted in subslot (slot/subslot
number).
6
Card (cc/rp/fp) removed from slot
(slot number).
6
Card (cc/rp/fp) inserted in slot (slot
number).
Configuring Call Home
OL-16506-10
Need help?