Remote/Local
• Switches between remote and local operation.
• To change the parameter setting during remote operation, use the communica-
tions function. To change the parameter setting during local operation, change the
Function
setting on the E5EK-T controller. You can check the parameter setting by both
communications and on the E5EK-T controller regardless of whether the control-
ler is switched to remote or local operation.
"
Setting
F Related description
Chapter 6 Using the Communications Functions
F Related parameters
See
"Communication stop bit" "Communication data length" "Communication par-
ity" "Communication baud rate" "Communication unit No." "Event input assign-
ment 1" "Event input assignment 2" "Event input assignment 3" "Event input
assignment 4" (option mode)
F Option units
E53-AK01/02/03
Model
Standby time
• Sets the time until program operation is started after the run instruction is issued.
Function
Setting
F Related description
4.7 Setting Running Conditions/Starting the program run/Standby operation
(page 4-20)
See
F Related parameter
"Standby time monitor" (level 0 mode)
Setting Range
": remote / "
": local
Setting Range
0.00 to 99.59
Conditions of Use
The communications function must be in
use.
Default
Unit
Hour, minute
Level 2 Mode
Default
0.00
5--25