Installing the Device
2.4 Installing the Chassis Ground Connection
2.
2.4
Installing the Chassis Ground Connection
If the ground terminal on the power supply module(s) is not connected to safety
Earth, a connection must be provided from the chassis ground terminal on the
RUGGEDCOM MX5000 chassis.
If the ground terminal on the power supply module(s) is connected to safety Earth,
a connection from the chassis ground terminal is not required.
1.
18
2
2
Screw
1
Adapter
2
Figure 2.2
Panel Mounting
Install the supplied screws to secure the adapters to the panel. Make sure the
screws are torqued to 2 ± 0.1 N·m (18 ± 1 lbf-in)
NOTICE
Position the grounding cable and external tooth lock washer on the
RUGGEDCOM MX5000.