A p p e n d i x G : U s i n g t h e I / O s i g n a l s o f M a t r o x I r i s E - S e r i e s
C o n n e c t i n g t o a n i n d u c t i v e l o a d d e v i c e
To connect your Matrox Iris E-Series to an inductive load device, you must first
connect a high-voltage diode between them. The diode protects your Matrox Iris
E-Series from high voltage, caused when disconnecting from the inductive load
device.
You should connect the negative side of the load (anode) and a Matrox Iris E-Series
output signal to the external diode. In addition, you should connect the positive
side (cathode) of the load to a +24 V power supply. When the Matrox Iris E-Series
output signal is enabled, the negative side of the load is reduced to 0 V, and 24 V
appears across the circuit.
Matrox Iris
input and
output
connector
13
24
20
7
14
1
GND
External diode
output signal
+24V
Sinking
input
Inductive
load
device