Communication Parameter Setting; Communication Parameters - Edwards STP-iS1607 Series Instruction Manual

Turbomolecular pumps
Table of Contents

Advertisement

5.2.3

Communication parameter setting

The factory setting of COM1 is shown in Table 17. To set communication parameters, use the STP-
Link (optional accessory) or the display unit iDT-001 or iDT-002 (optional accessory).
Communication
parameter
Baud rate
Bit length
Stop bit
Parity
Driver type
*1
RS485ID
Terminator
*1
It is used in RS485 multi.
STP-iS1607 Series Turbomolecular Pump
Factory setting
9,600 bps
8 bit
1 bit
None
RS232/RS485 single
1
Not use
Table 17 - Communication parameters
PC setting example
1,200 to 56,000 bps
7, 8 bit
1, 2 bit
None, Even, Odd
RS232/RS485 single, RS485 multi
1 to 127
Not use, Use
5
MT-94E-001-C
Page 75