Riello NXHP Series Installation, Operation And Maintenance Instructions page 75

Table of Contents

Advertisement

Available languages

Available languages

7 -PARAMETERS OVERVIEW
Par.
Modbus Mnemonic Description
373 0175H
pmp_st
Water Pump Starts Nb
374 0176H
pmp_hr
Water Pump Run Hours
379 017BH
wearfact
Unit Wear Factor
380 017CH RUN2_RST User Runtime Reset
381 017DH
comp_hr
Compressor Run Hours
382 017EH
back_hr
Backup Running Hours
383 017FH
cool_hr
Cooling Mode Hours
384 0180H
heat_hr
Heating Mode Hours
385 0181H
dhw_hr
DHW Mode Hours
386 0182H
md_hr
Defrost Mode Hours
387 0183H
fd_hr
Free Defrost Mode Hours
Energy consumed in
388 0184H
nrg_heat
Heat
389 0185H
nrg_cool
Energy consumed in Cool
Energy consumed in
390 0186H
nrg_dhw
DHW
391 0187H
CHIL_S_S Unit Start/Stop
392 0188H
HC_SEL
Heat/Cool Select
393 0189H
EMSTOP Emergency Stop
Heat Home Setpoint
401 0191H
hwoccstp
(Water)
402 0192H
hwunooff
Heat Sleep Offset (Water)
403 0193H
hwecooff
Heat Away Offset (Water)
Cool Home Setpoint
404 0194H
cwoccstp
(Water)
405 0195H
cwunooff
Cool Sleep Offset (Water)
406 0196H
cwecooff
Cool Away Offset (Water)
407 0197H
hw_hyst
Heat Hysteresis (Water)
408 0198H
cw_hyst
Cool Hysteresis (Water)
409 0199H
hcurvoff
Heat Curv Max Stp Offset
410 019AH
ccurvoff
Cool Curv Min Stp Offset
411 019BH
dhwecstp DHW Eco Setpoint
412 019CH
leg_stp
DHW Anti-Legionella Stp
413 019DH
dhw_stp
DHW Setpoint
414 019EH
dhw_hyst DHW Hysteresis
421 01A5H
htoccstp
Heat Home Setpoint (Air)
422 01A6H
htunooff
Heat Sleep Offset (Air)
423 01A7H
htecooff
Heat Away Offset (Air)
424 01A8H
cloccstp
Cool Home Setpoint (Air)
425 01A9H
clunooff
Cool Sleep Offset (Air)
426 01AAH
clecooff
Cool Away Offset (Air)
Home AntiFreeze
427 01ABH
freezstp
Setpoint
428 01ACH
deltastp
Air Delta Setpoint
429 01ADH
iat_fact
IAT Reset Factor
Min
Max
0 = Do nothing, 1 = Reset Hours only, 2 
= Reset Energy Counters only
0
3
3 = Reset All runtimes (hours & energy 
0
1
0
1
0
1
[Disable/Enable]
20
75
-20
0
-20
0
5
20
0
10
0
10
0,5
2
0,5
2
-5
5
-5
5
30
75
50
75
30
75
0,5
10
12
34
-10
0
-10
0
20
38
0
10
0
10
6
12
0,2
1
0
2
Range
Default
N.A.
0
N.A.
0
N.A.
0
0
counters)
N.A.
0
N.A.
0
N.A.
0
N.A.
0
N.A.
0
N.A.
0
N.A.
0
N.A.
0
N.A.
0
N.A.
0
[Stop/Start]
[Heat/Cool]
N.A.
45
N.A.
0.0
N.A.
-5,0
N.A.
12
N.A.
0
N.A.
5
N.A.
2
N.A.
1
N.A.
0,0
N.A.
0,0
N.A.
45
N.A.
60
N.A.
50
N.A.
5
N.A.
19
N.A.
-2,0
N.A.
-4,0
N.A.
26
N.A.
2
N.A.
4
N.A.
6
N.A.
0,5
N.A.
0
Unit
Table
-
RUNTIME1
h
RUNTIME1
-
N.A.
-
RUNTIME2
h
RUNTIME2
h
RUNTIME2
h
RUNTIME2
h
RUNTIME2
h
RUNTIME2
h
RUNTIME2
h
RUNTIME2
kWh
RUNTIME2
kWh
RUNTIME2
kWh
RUNTIME3
-
AQUASMRT
-
AQUASMRT
-
AQUASMRT
°C
WAT_STP
K
WAT_STP
K
WAT_STP
°C
WAT_STP
K
WAT_STP
K
WAT_STP
K
WAT_STP
K
WAT_STP
K
WAT_STP
K
WAT_STP
°C
DHW_STP
°C
DHW_STP
°C
DHW_STP
K
DHW_STP
°C
AIR_STP
K
AIR_STP
K
AIR_STP
°C
AIR_STP
K
AIR_STP
K
AIR_STP
°C
AIR_STP
K
AIR_STP
AIR_STP
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxhp 004Nxhp 006Nxhp 008Nxhp 010Nxhp 012Nxhp 014

Table of Contents