VisuNet FLX System
Electrical Installation
5.2.2

Equipotential bonding of the pedestal

Procedure
1.
Connect the equipotential bonding of the pedestal with the PB stud on the bottom plate of
PEDESTAL-AG-3200-*
2.
Fasten the hardware with a torque of 7,5 Nm.
Figure 5.5
The vertical stand provides on the base plate a grub screw for the connection of an equipoten-
tial bonding conductor. Cables for equipotential bonding shall have a diameter of at least 4
2
mm
and cable lugs shall be used.
Equipotential Bonding Concept
Figure 5.6
Setup of the equipotential bonding rod connection. To get a safe connection with an adequate
contact pressure, it is essential to adhere the specifications.