Pepperl+Fuchs VisuNet FLX System Manual page 18

Extended temperature range
Hide thumbs Also See for VisuNet FLX System:
Table of Contents

Advertisement

VisuNet FLX System
Product Description
Directive conformity
Directive 2014/34/EU
RoHS
Directive 2011/65/EU
(RoHS)
Ambient conditions
Operating temperature
Storage temperature
Relative humidity
Climatic conditions
Altitude
Shock resistance
Vibration resistance
Mechanical specifications
Degree of protection
Material
Installation
Mass
Dimensions
International approvals
UL approval
Approved for UL OrdLoc
Approved for UL HazLoc
ATEX approval
ATEX certificate
18
EN IEC 60079-0:2018
EN IEC 60079-7:2015/A1:2018
EN 60079-31:2014
EN IEC 63000:2018
-20 °C ... 50 °C (-4 ... 122 °F)
-20 °C ... 65 °C (-4 ... 149 °F)
max. relative humidity 93% at 50°C (non-condensing) according
to EN60068-2-78
Passive cooling, no rotating parts
Operating altitude max. 2000 m
18 shocks 15 g, 11 ms all axis, IEC 60068-2-27
10 ... 150 Hz, +/- 0.075 mm, 1 g, 10 cycles per axis according to
EN60068-2-6
IP66 / Type 4X
Housing: Aluminium EN AW-5754
System with enclosure
approx. 11.4 kg
aprprox. 13.4 kg with AC Power Supply
with top sunshield: + approx. 1.6 kg
with top and side sunshield: + approx. 3 kg
577 mm x 466 mm x 233 mm
UL approval E223772
UL61010-1 Ed.3
UL 61010-2-201 Ed2
CAN/CSA C22.2 No 61010-1-12
CAN/CSA C22.2 No 61010-2-201
Mounting in
CL I, DIV 2, GP A-D, T4
CL II, DIV 2, GP F, G, T4
CL III
Mounting in
CL I, ZN 2, IIC, T4
CL II, ZN 22, IIIB, T85°C
CL III, ZN 22, IIIA, T85°C
UL 22 ATEX 2481X

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VisuNet FLX System and is the answer not in the manual?

Table of Contents