VisuNet FLX System

Electrical Installation

5
Electrical Installation
5.1

General Electrical Installation Information

Warning!
Danger of explosion!
Only use cables and connection lines which are suitable for the application within a tempera-
ture rating of at least 80°C.
Danger!
Explosion hazard from wrong or missing equipotential bonding!
Wrong or missing equipotential bonding can cause sparks. This can ignite the surrounding
potentially explosive atmosphere.
Connect the equipotential bonding of the device! Observe the equipotential bonding require-
ments.
Ensure that external equipotential bonding connections exist, are in good condition, and are
not damaged or corroded.
Danger!
When installing the VisuNet FLX system, always ensure a proper equipotential bonding of all
components, including housing and mounting parts (e.g., pedestal and wall bracket) with a
cable diameter of at least 4 mm
The VisuNet FLX is shipped with the following equipotential bonding (PB) wiring connections, if
the AG-3200-* housing option is selected:
- PB wire from the computing platform housing PE stud to the AG-3200-*housing PB stud.
- PB wire from the lens head screw of the panel to the adapter plate of the AG-3200-* housing
PB stud.
Note
Refer to the manuals of the individual VisuNet FLX components for more information on
electrical installation and wiring.
2
(~12-24 AWG) in accordance with IEC 60079-14.