EPSON WF-C5790/WF-C5790a/WF-C5710/ET-8700/WF-C5210/WF-C5290/WF-C5290a
PRINT POSITION OFFSET IN FEED DIRECTION
Symptom
The image is offset in the sub scanning (feed) direction (top and bottom
margins are not equal) and the top or bottom edge of the image is cut off.
Main scanning line (CR operation) direction
Figure 4-8. Print Position Offset in Feed Direction
Cause
The paper that is being used is inappropriate.
Paper settings of main unit or printer driver settings are inappropriate.
Paper feeding failure
PE Sensor Lever failure
PE Sensor is dirty, failure, or has deteriorated.
CR Unit (PW Sensor) is dirty or failure.
Troubleshooting
Troubleshooting procedure
Revision A