not the best choice.
3. Speaker Delay: If desired, an audio delay may be inserted ahead of the
monitor speakers. This delay may range from 0 to 170 mS. Typically, delay is
used to align the monitored audio with a video monitored signal.
4. Input Selection: Audio from any of the input sources may be applied to the
monitoring scheme in any way. For example, you may have 2 AES channels,
and along with 2 analog channels assigned your choice of meters. A Preset
Input/Output Matrix is provided on the lower right side of the screen to
allow you to assign each channel. Simply select each input source, one at a
time, and then check the boxes in the Matrix to apply each input channel
number to a metered channel number. They do not have to be applied in any
specific order. The order of assignment should be chosen to make it easy for
the operator to understand.
5. Autofill Selection: If you simply want to map all 8 input channels to all 16
meters in the same order, click the Autofill button. The Preset
Input/Output Matrix will automatically fill out. To remove all mapping,
click the Reset button that is adjacent to the Autofill button.
6. Cluster Definition and Naming: Channel Clusters are a series of channels
that are all associated with monitoring the same signal. For example, a
Stereo Cluster consists of two channels that together monitor a stereo signal.
Clicking a Cluster Info box opens a Cluster selection box.
In the Cluster box, you can select the type of Cluster from a pull down
selection. The available Cluster Type selections are:
Mono: The channel will appear within a single-channel cluster.
Stereo: The channels will appear within a two-channel cluster.
Surround 5.1: The channels will appear within a 6-channel cluster.
Surround 7.1: The channels will appear within an 8-channel cluster.
Custom: You may define a 0 to 8 channel cluster.
Multichannel clusters will expand to the right and overwrite any clusters on
overlapping meter positions.
By default, all odd numbered channels will map to the left speakers and all
even numbered channels will map to the right speakers. You may change this
using the crosspoint selections in the Input/Output Matrix.
A default name will be chosen and it will appear on the metering screen. You
may name the Cluster anything you want by simply changing the words
within the Cluster Name field.
When finished, click Update. To undo your change, click Reset. To undo all
of the Cluster changes for the 8 channels, click Reset All.
7. Speaker Assign: Speaker assignments are made automatically when a
cluster is set. However, it can be that in an actual signal, the channel
assignments may be different than what the automatic assignment assumes.
A speaker assignment adjustment is provided for each channel, should you
need to override the automatic settings.
the function of each channel so that the Loudness calculations will be
accurate.
lets you change the current setting.
eAMP1-S8-DA
Clicking a Speaker Assign button on a channel opens a box that
Page 58
It is important to accurately assign