Analog Configuration - Wohler eAMP1-S8-DA User Manual

1ru multi-channel audio monitor
Table of Contents

Advertisement

Analog Configuration

Touching the Analog Config button in the System Options Menu displays the
Analog Config screen. Contained in this menu is an Analog Reference as
illustrated in Figure 2-22. The parameters set on this screen pertain to the Analog
Input and Analog Output DB25 and XLR connectors on the rear panel of the
eAMP1-S8-DA.
There is only one setting on the Analog Reference menu:
1. Analog Reference: This setting adjusts the relationship between the
monitored digital signal level and the analog signal level that is output from
both of the DB25 and both of the XLR connectors on the back panel. The
default setting is -20 Dbfs = +8 dBu as shown in Figure 2-23. The range of
possible settings is as follows:
a. -20 dBFS = +8 dBu
b. -20 dBFS = 0 dBu
c. -22 dBFS = +4 dBu
d. 0 dBFS = +15 dBu
e. -16 dBFS = +4 dBu
f. -18 dBFS = +4 dBu
g. -18 dBFS = 0 dBu
h. -20 dBFS = +4 dBu
Touching Save will save any changes made, or touching Cancel will return you to
the System Options menu without saving.
eAMP1-S8-DA
Figure 2-22: Analog Configuration Menu