Wohler eAMP1-S8-DA User Manual page 30

1ru multi-channel audio monitor
Table of Contents

Advertisement

Scale
Bottom Limit
AES
-72 dBFS
DIN
-53 dBr
BBC
-13.25 dBr
VU
-45 dBr
EXTVU
-56 dBr
NORDIC -44 dBr
EBU
-13.25 dBr
2. Ballistics: The Bar and Float ballistics associated with the selected meter
scale are displayed. Refer to Table 2-5. Ballistic timings are valid only at 48
kHz.
Ballistics
VU
IEC Type I
IEC Type II
None
3. Segment Boundary: The Boundaries between the Upper and Middle
segments (red and yellow) and the Middle and Lower segments (yellow and
green) can be varied. Touch the left or right arrows to select the Upper or
Middle scale. Rotate the Channel knob to adjust the lower boundary of the
selected segment in 1 dB steps.
When you have made your choices, touch Save to retain them. Touch Back to
exit this screen.
eAMP1-S8-DA
Table 2–4: Meter Limits and References
Default
Top Limit
Reference
0.0 dBFS
0 dBFS = 0 dBFS
+5.5 dBr
-15 dBFS = 0 dBr
+13.0 dBr
-18 dBFS = 0 dBr
+3.5 dBr
-20 dBFS = 0 dBr
+16.0 dBr
-20 dBFS = 0 dBr
+12.5 dBr
-18 dBFS = 0 dBr
+13.0 dBr
-18 dBFS = 0 dBr
Table 2–5: Meter Timings
Rise
Not Specified
5 ms to reach -2 dB of
settled reading
10 ms to reach -2 dB of
settled reading
Bar or Floating Segment Not Displayed
Page 30
Default Color
Default Ballistics
Bounds
Lower
Upper
Float
IEC
-30 dBFS -20 dBFS
Type I VU
-5 dBr
0 dBr
0 dBr
8 dBr
-3 dBr
0 dBr
-10 dBr
0 dBr
-10 dBr
0 dBr
0 dBr
8 dBr
Fall
Level
Time
Change
-20 dB
1.7 sec.
-24 dB
2.8 sec.
Bar
IEC Type I
IEC Type I
VU
VU
IEC Type I
IEC Type I