By design, the supplied AC mains power cord will only plug into a
three-prong grounded outlet for your safety. If the plug does not fit
into the outlet, contact an electrician to replace the obsolete outlet.
1. Network Port: This Ethernet port can connect to either a LAN or to a PC
to let you perform metering, monitoring, and configuration remotely. The
Wohler Web GUI is described in Chapter 4 of this manual. Third party
equipment, which can use API commands to view and change product options,
can also be plugged into this port. However, use of the API commands requires
that the OPTe Package be purchased. The API is described in Appendix E of
this manual.
2. AES Inputs: This HD-15F connector accepts 4 AES3id digital audio pairs
(8 channels) at a 48 kHz sample rate. Refer to Figure 2-3 for the pinout of
this connector. The easiest way to interface with this connector is to use
an HD-15 to VGA adaptor cable. Channels are selected as AES 1-8.
3. AES Outputs: This HD-15F connector provides 4 AES3id digital audio
pairs (8 channels) at a 48 kHz sample rate from selected monitored
sources. Refer to Figure 2-10 for the pinout of this connector. The easiest
way to interface with this connector is to use an HD-15 to VGA adaptor
cable. These outputs are not controlled by the Volume and Balance
controls. Monitored channels 1 and 2 are sent from AES-1, channels 3 and
4 are sent from AES-2, channels 5 and 6 are sent from AES-3, and
channels 7 and 8 are sent from AES-4. If the OPTe Package and the OPTe
Output Routing option are purchased, these output channels may be
sourced by any selected input channels.
4. Unbalanced Analog Inputs: These female RCA jacks provide two
unbalanced analog inputs:
5. Balanced Analog Outputs: These male XLR connectors provide two
balanced analog outputs:
mix of audio as monitored by the internal speakers and can either be
adjusted by the Volume and Balance controls or configured for a fixed
line level output. The Analog Outputs are standard on the eAMP1-S8-
eAMP1-S8-DA
Figure 2-3: AES HD-15F Connector Pinout
Left
Left
Page 12
and
.
Right
and
. The source of these signals is the
Right