Related topics
X16/17 – Digital Inputs, page 53
Temperature Sensor of the Motor, page 66
7.8.2
Digital Inputs – VF
If more than 8 parameter sets are used, not all functions can be assigned freely any-
more. If more than 32 parameter sets are used, the measuring system NAMUR can not
be used anymore.
12-pole Mini-Combicon connector, suitable for mating connector MC 1,5/ 12-ST-3,81
(Phoenix)
Mating con-
Pin
I/O
nector X16
1
I
2
I
3
I
4
I
5
I
6
I
7
I
Drive System SD2S - Hardware Description 0362x49xx / 0362129xx
Name
Configurable functions
▶ No function
IN0
▶ Switch on type 1 (without edge evaluation)
▶ Switch on type 2 (with positive edge)
IN1
▶ No function
▶ Quick stop type 5 (with slow down ramp and controller off)
▶ Quick stop type 6 (with quick stop ramp and controller off)
▶ Quick stop type 7 (with slow down ramp and reset)
▶ Quick stop type 8 (with quick stop ramp and reset)
▶ Operation enable
▶ Operation enabled with error reset
▶ MOP up
▶ MOP down
▶ No function
(1)
IN2
▶ Operation enable
▶ Operation enabled with error reset
▶ Error reset
▶ External hardware OK
▶ Speed direction
▶ MOP up
▶ MOP down
▶ No function
(1)
IN3
▶ Parameter set Bit 0
▶ MOP up
▶ MOP down
▶ No function
(1)
IN4
▶ Parameter set Bit 1
▶ Internal target value Bit 3
▶ MOP up
▶ MOP down
▶ No function
IN5
▶ Parameter set Bit 2
▶ Internal target value Bit 2
▶ MOP up
▶ MOP down
▶ No function
IN6
▶ Error reset
▶ External hardware OK
▶ Speed direction
▶ Teach no-load current
▶ Parameter set Bit 3
▶ Internal target value Bit 1
▶ MOP up
▶ MOP down
Connector Pin Assignment