Status Display and Error Messages
Code
Error message
E46
1
Safety circuit (Safety X10)
(0x52E)
(1326d)
2
Initialization error: internal
hardware of safety controller
3
Incorrect data/parameters in
process sequence
4
Error in function parameters
for a functional part
5
Timeout of monitoring func-
tions
6
Monitoring of OSSD signals
and output stage enable
7
Monitoring of motor phases
8
Frequency exceeded
9
Communication error between
DSP and safety controller
E47
Drive parameters not activated
(0x52F)
(1327d)
E55
Firmware stopped by ESC
(0x737)
(1847d)
E56
Device configuration
(0x738)
(1848d)
E57
Faulty or no firmware
(0x739)
(1849d)
E58
FPGA watchdog triggered
(0x73A)
(1850d)
E59
No drive parameters loaded
(0x73B)
(1851d)
E60
Drive parameters incorrect
(0x73C)
(1852d)
E61
Logic coding missing or incorrect
(0x73D)
(1853d)
E62
Error in electronic type plate
(0x73E)
(1854d)
(1)
For servo motors with commutation via an incremental motor measuring system, the warning W17 "Unknown commutation
angle" is signaled. After a restart of the device, the phasing of the motor measuring system starts automatically (magnetic
alignment).
80
Error reaction
Drive is immediately disabled, mo-
tor coasts to standstill without con-
trol.
Power output stage can not be acti-
vated.
Device stops in BIOS.
Device stops in BIOS.
Device stops in BIOS.
Device stops in BIOS.
Device stops in BIOS.
Device stops in BIOS.
Device stops in BIOS.
Device stops in BIOS.
Drive System SD2S - Hardware Description 0362x49xx / 0362129xx
Possible reason
1
Safety circuit STO is activated
when the output stage is active; in-
put SAFE A and/or input SAFE B
were triggered.
2
Safety function SFM/SLOF: error in
according hardware components of
the safety controller
3
Safety function SFM/SLOF: faulty
PLC telegrams
4
Safety function SFM/SLOF: para-
meter is out of limits
5
Safety function SFM/SLOF: error in
according hardware components
6
Safety function SFM/SLOF:
▶ wrong OSSD signals
▶ defective OSSD relay
▶ defective multiplexer
7
Safety function SFM/SLOF: defec-
tive motor cable (broken cable)
8
Safety function SFM/SLOF:
▶ set reference speed value is too
high
▶ limit value for Safe Limited Out-
put Frequency is parameterized
incorrectly
▶ OSSD signals are set incorrect-
ly
9
Safety function SFM/SLOF: com-
munication between DSP and safe-
ty controller is disturbed
▶ Drive start is not acknowledged by
master yet (configurable by parame-
ters in software).
▶ During boot-up, the device received
an ESC sequence at the serial inter-
face.
▶ During boot-up the device detected
that hardware, firmware parameters
and logic are not consistent;. A de-
tailed error description is received by
a parameter download.
▶ During boot-up the device detected
no firmware or a faulty firmware.
▶ FPGA process monitoring has
been triggered;. Please contact
SIEB & MEYER.
▶ Device is not parameterized (status
of delivery).
▶ Parameter set of the device is not
valid (CRC error).
▶ Logic programming of the device is
not valid.
▶ Type plate is not programmed
or faulty. Please contact
SIEB & MEYER.
Need help?
Do you have a question about the SD2S and is the answer not in the manual?