The Occupational Safety and Health Administration (OSHA) only accepts devices that
have been approved by an authorized NRTL laboratory (Nationally Recognized Testing
Laboratory) and labeled with an appropriate test mark. An NRTL authorized by OSHA
checks the legitimate status of the test mark by inspectors of the manufacturing sites,
for example.
TÜV SÜD Product Service is an NRTL approved by OSHA and undertakes product certi-
fications for industrial controls, electric drives and other products. The following link lists
the approved NRTL laboratories:
https://www.osha.gov/dts/otpca/nrtl/nrtllist.html
The tested devices are labeled with the following symbol:
The device series 0362x49xx/0362129xx is tested accoring to the harmonized standard
IEC / UL 61800-5-1: "Standard for Adjustable Speed Electrical Power Drive Systems -
Part 5-1: Safety Requirements - Electrical Thermal and Energy"
▶
Date: 2022-05-04
▶
Device variants:
0362149EF / 0362249EF / 0362129EF
0362149IF / 0362249IF / 0362129IF
0362149EC / 0362249EC / 0362129EC
0362149IC / 0362249IC / 0362129IC
0369853EF / 0369853FF
▶
Certificate number: U10 096098 0009 Rev. 00
▶
Certificate data base:
https://www.tuev-sued.de/product-testing/certificates
(Enter "SIEB & MEYER AG" in the search field.)
http://www.tuev-sued.de/industry-and-consumer-products/-services/nationally-
recognized-testing-laboratory-nrtl
http://www.tuev-sued.de/industry-and-
consumer-products/-branches/industrial-electronics/
2.2
NRTL Requirements
Points of Exceptions of the Test Procedure and Conditions of Acceptability
Conditions of Acceptability:
▶
When installing, requirements of mentioned Test Standards and Installation Guide
have to be fulfilled.
▶
The equipments are intended for use in end-use application within final enclosure
to maintain a Pollution Degree 2 or equivalent environment.
▶
The final enclosure has to fulfill the requirements for the protection in case of direct
contact.
▶
The maximum ambient temperature is +40 °C.
▶
The Terminal blocks are suitable for factory wiring only.
▶
The end-use application must be equipped with a Branch Circuit Protection that
meets the requirements of the NRTL certificate.
▶
All Branch Circuit Protection shall have characteristic B.