X14 - Usb; X14 Usb; X10 - Safety (Sto); X10 Safety - SIEB & MEYER SD2S Hardware Description

Drive system
Hide thumbs Also See for SD2S:
Table of Contents

Advertisement

Connector Pin Assignment
7.5
X14 – USB
Communication interface to the connected PC
4-pole female USB connector, type B
X14
7.6
X10 – Safety (STO)
Safety circuit and restart lock (STO)
6-pole Mini-Combicon connector, suitable for mating connector MC 1.5/ 6-ST-3.81
(Phoenix)
Mating con-
nector X10
(1)
The 24 V output is not suited to supply external safety circuits because an external voltage source is
necessary to comply with the applicable standards. If the safety function (STO) is not required, this voltage
is only used to bridge the pins 1 and 3.
Specification of terminal connections
Conductor cross-section solid/stranded: 0.14 to 1.5 mm²
Tightening torque: 0.22 to 0.25 Nm
Note
The power supply unit is only activated when SAFEA and SAFEB are connected. If the
safety function (STO) is not required, pin 1 and pin 3 must be bridged to pin 6.
Related topics
safety circuit (STO), page 48
Safety Circuit / Restart Lock (STO), page 87
32
Pin
I/O
Name
1
VCC
2
I/O
DN
3
I/O
DP
4
I/O
GND
Pin
I/O
Name
Meaning
1
I
SAFEA /
Enable of the safety circuit
▶ Continuous load at 24 V > 160 mA/24 V, de-
OSSD1
▶ Startup peak current per device is limited to
2
GND
Reference potential
3
I
SAFEB /
Enable of the safety circuit
▶ Permanent load approx. 15 mA/24 V
OSSD2
▶ Startup peak current is negligible under nor-
4
n.c.
5
n.c.
6
O
Logic voltage 18 to 28 volts (uncontrolled)
(1)
24 V
Drive System SD2S - Hardware Description 0362x49xx / 0362129xx
Description
5 V voltage supply for USB
Data−
Data+
Ground
pendent on the device performance
2 A/24 V.
mal conditions.