Connection of the temperature sensor when solar heating is used
45-46
+/- output for the connection of a filling solenoid valve (24 V)
47-48
Output +/- bus data supply (24 V)
49-50
DATA output +/- BUS mode for the connection of Pentair equipment (Intelliflo VSF filter
pump, Invertemp heat pump)
51 to 58
Connection of swimming pool projectors (12 V/50 W unit)
Prohibition
Never supply voltage (Neutral + Phase) to IN, AL inputs and AUX outputs!
In order to operate the outputs correctly, it is necessary to configure them on the website.
These settings may be partly carried out on the interface of the INTELLIPOOL, through the related
menus.
4.8.3
Connection of the " PENTAIR VSF " filter pump
The connection of the supply phase, the neutral and the earth must be made through the
connection terminal block according to terminals 3 and 4 (for the earth connection: proceed to the
connection on the dedicated terminal block).
The connection of the control cable must be carried out on the terminal blocks 47 and 48.
4.8.4

Connection of the heat pump power supply (if installed)

The connection of the supply phase, the neutral and the earth must be made through the
connection terminal block according to terminals 1 and 2 (for the earth connection: proceed to the
connection on the dedicated terminal block).
The power consumption of the heat pump shall not exceed 20 A in single phase.
The control of the operation of the heat pump must be connected to terminals 21-22 (refer to the
instructions for the heat pump used).
The connection of the BUS control cable for a Pentair heat pump (Invertemp) must be made on the
terminal blocks 47 and 48, do not use the terminal blocks 21-22.
Info
The connection of the Bus driver cables (IntelliFlo, InverTemp) must be carried out in the
Intellipoolbox on the RS-485 connectors.