35 36
Connecting a component to launch an Auxiliary (X)
1. Connect the information socket contact directly to the chosen input (example terminals
37-38).
2. In the menu "Pool Properties > Menu Installation 4X Extension", see Menu installation 4X
Extension [
Page 47], select the input "Aux X (Status)" and customise the name if
necessary.
37 38
Connection of a piece of equipment in order to measure its activity time in the history.
1. Connect the contact directly. If the device does not have a contact, connect to a relay
according to Diagram 1bis.
2. In the menu "Pool Properties > Menu Installation 4X Extension", see Menu installation 4X
Extension [
Page 47], select the input "IN info 1 (terminal blocks 31-32) or 2 (terminal
blocks 33-34)" and customise the name if necessary.
Ref. SB-CU-IMP-058EBA / A - 11.05.2023
Installation and Operation Guide Version E-Box INTELLIPOOL - Installation
Dry contact Normally Open or Normally Closed depending on choice:
NO = Normally Open = allows filtration (closing it will immediately stop filtration)
NF = Normally Closed = allows filtration (opening it will immediately stop
filtration)
Dry contact whose closing will trigger the launch of the selected Aux
49 / 102