Connecting The "Single Speed" Filter Pump - Pentair E-Box MAESTRO Lite Installation And Operation Manual

Table of Contents

Advertisement

3-4
Connection of the heat pump power supply (230V 20A)
5-6
Variable Speed Pump Supply Connection (230V 15A)
7-8
Connecting the Pool Automatic Shutter Power Supply (230V 16A)
9-10
Connecting the Single Speed Filter Pump Power Supply (230V 4 – 6.3A)
11-12
Controlled connection of the supply for the dosing pump for pH regulation (230 V 1A)
13-14
Controlled connection of the power supply for the metering pump for the regulation of
liquid chlorine (230 V 2A)
15-16
Connection of the dry contact for the control of the electrolyser (flow detector)
17-18
Dry contact for pool lighting control (max 230V 8A)
19-20
Dry contact for pool heating control (max 230V 8A)
In order to operate the outputs correctly, it is necessary to configure them on the website.
These settings can be partly carried out on the Maestro interface, through the related menus.
4.8.2.2
Terminal block 2: Low voltage connection (12-24 V)
21-22
Connection of swimming pool projectors (12 V/50 W unit)
23-24
Connection of swimming pool projectors (12 V/50 W unit)
25-26
Connection of swimming pool projectors (12 V/50 W unit)
27-28
Connection of swimming pool projectors (12 V/50 W unit)
Prohibition
Never supply voltage (Neutral + Phase) to IN, AL inputs and AUX outputs
In order to operate the outputs correctly, it is necessary to configure them on the website.
These settings can be partly carried out on the Maestro interface, through the related menus.
4.8.3

Connecting the "Single Speed" filter pump

The connection of the supply phase, the neutral and the earth must be made through the
connection terminal block according to terminals 9 and 10 (for the earth connection: proceed to
the connection on the dedicated terminal block).
Ref. SB-CU-IMP-062EBLA / A - 11.05.2023
Installation and Operation Guide Version E-Box MAESTRO Lite - Installation
35 / 90