Aux Output Connections - Pentair E-Box INTELLIPOOL Installation And Operation Manual

Table of Contents

Advertisement

Installation and Operation Guide Version E-Box INTELLIPOOL - Installation
31 32
33 34
Connection of a flow sensor (for example that of the analysis chamber)
1. Connect the contact directly.
2. In the menu "Pool Properties > Menu Installation 4X Extension", see Menu installation 4X
Extension [
Page 47], select the input "Flow Detector" and customise the name if
necessary.
31 32
4.10.3

AUX output connections

Info
The outputs (AUX 3 "Terminal blocks 25-26", AUX 4 "Terminal Blocks 27-28" and AUX 5
"Terminal Blocks 29-30") are dry contacts and do not provide any voltage.
Connection of a pH/flocculant/algicide pump
1. Connect the 230 V AC or 24 V DC peristaltic pump according to the corresponding diagram.
2. In the menu "Pool Properties > Menu Installation 4X Extension", see Menu installation 4X
Extension [
Page 47], select the output "pH" and customise the name if necessary.
50 / 102
1 - Dry contact whose closing time will be recorded in the history (such as a
water meter type filling sensor)
1a - Installation of a relay closing a switch. Use a relay compatible with the
voltage of the element to be monitored (such as a presence sensor)
Ref. SB-CU-IMP-058EBA / A - 11.05.2023