General Information; California Proposition; Pump Features; Power Supply - Pentair Hydromatic Novus 4000 Installation And Service Manual

Standard electrical controls
Table of Contents

Advertisement

General
Information
Thank you for purchasing your
Hydromatic
Novus
®
Panel. To help ensure years of
trouble-free op er a tion, please read
the fol low ing manual carefully.
Before Operation:
Read
the
in struc tions care ful ly. Reasonable
care and safe meth ods should be
practiced. Check local codes and
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product.
Read this manual
completely before using this
product and refer to it often for
con tin ued safe product use. DO
NOT THROW AWAY OR LOSE
THIS MAN U AL. Keep it in a
safe place so that you may refer
to it often.

CALIFORNIA PROPOSITION

65 WARNING:
This product and
related
accessories
chemicals known to the State of
California to cause cancer, birth
defects or other reproductive
harm.
Pump
Introduction
The NOVUS 4000 is a general
purpose pump controller designed
to control up to 3 pumps, in
either pump up or pump down
applications. It sequences pumps
on and off in response to changes
in level, pressure, or flow. The
primary sensor input is a 4 to 20
Ma. current loop which can be
2
connected to any sensor that has
a 4-20 Ma. output. When used
to control level in a tank or well,
the input is usually connected to a
pressure transducer or ultrasonic
transmitter. A loop power supply
Control
is provided in the NOVUS 4000.
The NOVUS 4000 can be
configured for many applications
using its easy to use front panel
user interface.
following
using removable terminal block on
the back cover. Field replacement
is easy because the terminal blocks
unplug from the controller so no
wires need to be disconnected.
Unpacking Panel:
Remove panel from carton.
When un pack ing unit, check for
con cealed damage.
damage must be made at the
receiving end through the delivery
carrier.
processed from the factory.
Pump
Features
• 32 character alpha-numeric
liquid crystal display for
contain
level, status, and setpoint
information.
• Alternation selector switch on
front panel to turn alternation
on and select the lead pump if
alternation is off.
• Simple menu structure for
easy display and modification
of
configuration.
• Built-in elapsed time meters
for all pumps.
nonvolatile
examined from the front panel.
• 4 to 20 Ma. main sensor
input with loop power supply
for easy connection to most
transducers and transmitters.
Wiring is easy
Claims for
Dam age cannot be
setpoints
and
setup
They are
and
easily
Adjustments are provided for
both scale and offset.
• Inputs for pump seal leak
sensors
and
pump
temperature
sensors
red fail lights for out of
specification conditions.
• Fully scalable 4-20 Ma. level
output transmitter.
• Built-in single float backup
system
for
pump
applications.
• Three auxiliary inputs which
can be pump disable or pump
run confirmation inputs for a
fail to start test.
• Built-in horn relay with
internal and input for external
mute button.
• Relay outputs for both high
and low level alarms with
adjustable setpoints.
• Individually
setpoints for up to three
pumps.
• All inputs are filtered and
transient protected.
• Built-in
software,
programming required.
• All inputs operate on low
voltage and current.
• Input power is 115V AC,
internally fused and transient
protected.
• All terminal strips unplug
without removing the wires
for easy field replacement.
Power
Supply
WARNING: Do not attempt to
wire this control box unless you
have a good working knowledge
of electricity and are familiar
over
with
down
selectable
no

Advertisement

Table of Contents
loading